Broad FX model range
Catalog internal diameters extend from 25 to 660 mm, with model-specific feed and discharge sizes.
Request a quote Original catalog reference. Please request current photographs for the configuration you need.
Hydrocyclones
Hydrocyclone clusters for classification, desliming, coarse-particle removal and selected dewatering duties.
FX25–FX660Price, quantity, lead time and payment terms are confirmed in your quotation.
PRODUCT OVERVIEW
Feed enters tangentially into a circular body. Centrifugal action moves coarser, heavier particles toward the wall, where they spiral downward with the concentrated discharge; finer material exits through the upper overflow.
The catalog identifies classification and desliming ahead of fine-particle separation, as well as check classification and control classification in grinding circuits. It also describes coarse-particle removal from wastewater and some dewatering uses.
Model selection depends on feed size, operating pressure, overflow and underflow dimensions, separation target and throughput. The tabulated capacities refer to stated reference conditions and should not be treated as capacity at every pressure.
PRODUCT CHARACTERISTICS
Catalog internal diameters extend from 25 to 660 mm, with model-specific feed and discharge sizes.
The tangential entry and centrifugal flow separate material into overflow and concentrated underflow streams.
The brochure specifies a reference feed pressure of 0.1 MPa and an intermediate overflow diameter for capacity values.
Inlet, overflow, underflow and cone-angle choices are listed by model and must be matched to the duty.
TECHNICAL INFORMATION
Catalog reference values for this product family. Final supply specifications are confirmed against your application and approved drawing.
| Catalog series | FX25, FX50, FX75, FX100, FX125, FX150, FX200, FX250, FX300, FX350, FX500, FX660 |
|---|---|
| Internal diameters listed | 25–660 mm |
| Feed arrangement described | Pressure or gravity feed, according to configuration |
| Separation principle | Tangential inflow and centrifugal separation |
| Catalog capacity reference condition | Feed pressure 0.1 MPa; intermediate overflow diameter |
Provide slurry properties, feed particle-size distribution, solids concentration, target cut size and required throughput to confirm the model and configuration.
DETAILED CATALOG DATA
Open a table to view the full schedule.
On smaller screens, scroll across to see all columns.
| Model | Internal diameter (mm) | Max feed size (mm) | Feed pressure (MPa) | Reference capacity (m³/h) | Separation size (μm) |
|---|---|---|---|---|---|
| FX25 | 25 | 0.2 | 0.1-0.5 | 0.1 | 2-10 |
| FX50 | 50 | 0.3 | 0.1-0.4 | 1 | 5-30 / 10-74 |
| FX75 | 75 | 0.6 | 0.1-0.4 | 2.5 | 5-40 / 20-74 |
| FX100 | 100 | 1 | 0.05-0.4 | 6.5 | 10-74 / 10-100 / 20-100 |
| FX125 | 125 | 1 | 0.05-0.4 | 9 | 20-74 / 20-100 |
| FX150 | 150 | 1.5 | 0.05-0.4 | 15 | 20-74 / 20-74 / 20-100 |
| FX200 | 200 | 1.5-2 | 0.05-0.4 | 30 | 30-100 / 30-100 / 40-100 |
| FX250 | 250 | 3 | 0.05-0.3 | 50 | 30-100 / 40-100 |
| FX300 | 300 | 5 | 0.03-0.3 | 60 | 40-100 / 50-150 |
| FX350 | 350 | 6, 7 | 0.03-0.3 | 90 | 50-120 / 50-150 |
| FX500 | 500 | 10-15 | 0.03-0.3 | 220 | 74-150 / 74-200 |
| FX660 | 660 | 16-20 | 0.03-0.2 | 350 | Confirm |
Catalog capacities are stated at 0.1 MPa feed pressure and an intermediate overflow diameter. The FX660 separation-size entry is unclear and requires confirmation. The brochure states that capacity changes with overflow diameter and the square root of feed pressure.
LET’S TALK ABOUT YOUR APPLICATION
Share your medium, dimensions and quantity. We’ll review the requirements for your quotation.